LA340-EDLM
Linear Axes

High performance stage (air bearing), travel 500 - 2000 mm, rep ± 0.3 µm, load 10 kg, speed 3090 mm/s
LA340-EDLM

 

Highly dynamic linear stage with air bearing

The drive concept of this linear axis is based on a dynamic linear motor and a linear measuring system, whereby it provides excellent flatness and straightness for highly dynamic applications. The granite structure with air bearings provides particle-free operation and a particularly long lifetime.

  • Ideal for particle-free, highly dynamic applications with high precision
  • Perfect flatness and high repeatibility up to ± 0.3 µm
  • Highly dynamic at speeds of up to 2060 mm/s
  • High load up to 50 kg
  • Suitable for maintenance-free 3-shift operation in clean room

Options:

  • Travels from 500 - 2000 mm
  • Versions for clean room, laboratory or production
  • Optionally with base plate and frame
  • Different measuring system resolutions up to 0.001 µm
  • Customized development with 3D design, prototypes, large series production

Fields of application

linear stage for precision scanning, setup of dynamic and highly precise multi-axis systems for cleanroom applications, semiconductor technology: wafer inspection, measurement of large substrates, TFT / OLED inspection, semiconductor printers for applying coating components, biotechnology: laboratory diagnostics, image-based inline monitoring, high-speed microscopy, laboratory automation

 

LA340-EDLM   -500-EDLM-L -1000-EDLM-L -1500-EDLM-L -2000-EDLM-L
Travel [mm] 500 1000 1500 2000
Repeatability unidirectional [μm] ± 0.3 ± 0.3 ± 0.3 ± 0.3
Repeatability bidirectional [μm] ± 0.4 ± 0.4 ± 0.4 ± 0.4
Accuracy [μm] ± 1.9 ± 3 ± 4.1 ± 5.2
Flatness [μm] ± 0.8 ± 1.5 ± 2.3 ± 3
Straightness [μm] ± 0.8 ± 1.5 ± 2.3 ± 3
Positioning speed [mm/s] 790 1210 1630 2060
Max. speed [mm/s] 1185 1815 2445 3090
Max. acceleration [m/s2] 16 25 35 40
Max. load Fx [N] 100 100 100 100
Max. load Fy [N] 500 500 500 500
Max. load Fz [N] 500 500 500 500
Max. torque Mx [Nm] 30 30 30 30
Max. torque My [Nm] 50 50 50 50
Max. torque Mz [Nm] 30 30 30 30
Pitch [µrad] ± 11 ± 16 ± 19 ± 20
Yaw [µrad] ± 11 ± 16 ± 19 ± 20
Length [mm] 1060 1560 2060 2560
Width [mm] 379 379 379 379
Height [mm] 310 310 310 310
Weight [kg] 370
Weight with frame [kg] 640
Bearing   Air Bearing
Type of drive system Linear Motor
Motor   Ironless Dynamic Linear Motor
Feedback   Linear Scale
Measuring system resolutions    0.05 µm (optionally up to 0.001 µm)
Material   Anodized Aluminum, Granite
Optional features   Frame
Variants cleanroom  up to clean room class ISO 6 (higher on request)
Variants beam   UV (DUV, EUV, X-ray, gamma on request)
Variants magnetism on request
Variants vacuum    on request

 

Related Products


Angepasstes System für Ihr Gesamtkonzept

Your customized system

Almost all atmospheric standard stages are unanodized with UHV lubrication for residual pressures up to 10-6 mbar and min. cleanroom class ISO 6 - or even better - available. Further stages for more demanding environments up to cleanroom class ISO 2, vacuum up to 10E-11 mbar or hard radiation you will find here:

Overview Clean Room & Vacuum Stages    Get in touch with our technical consultant

Ja, Lineartische können auch als Hubtische (Z-Richtung) sowie gestapelt (XY-Bewegungen verwendet werden).

Wichtig dafür ist, dass die maximale Kraft in Antriebsrichtung nicht überschritten wird. Die Kraft für die vertikale Positionierung wird in der Spezifikation bei Linear Stages unter Fx angegeben.

 

Steinmeyer Mechatronik GmbH mainly uses aluminum for the structure of the Linear Stages, because it efficiently dissipates local heat and quickly reaches a thermally stable state. This is a prerequisite for stable, precise systems. The lower stiffness of aluminum compared to steel is compensated by a slightly higher height of the stages or the use of hollow profiles. Note: An aluminum beam and a steel beam sag equally under their own weight!
In special cases, titanium is also used for magnet-free systems.

What surfaces are available?

Various surface options are available. Depending on the application, anodized and cleaned, alternative colors, aluminum cleaned and bare, bilatal or nickel are available for optimal process suitability (e.g. particularly high degrees of purity, resistance to cleaning with chemicals in the field of life science). Special surfaces are often necessary for UV, DUV or EUV (X-ray, gamma on request).

Depending on the requirements, various drive systems can be used. This can be recognized as an abbreviation in the name below:

  • Ground ball screws or lead screws with SM (stepper motor), DC motor or AC servo.
  • Electrodynamic linear motors (ironless or iron-core).
  • Piezomotors such as Piezo-Legs® or Nanomotion®.

Incremental scales made of steel or Zerodur® or Zeromet® are used as a feedback system in most cases. While this is sufficient for accuracy in the single-digit micrometer range, it makes sense to use interferometric position feedback for accuracy requirements below one micrometer. In systems with “open loop”, i.e. without a measuring system, only precision in the double-digit micrometer range can be achieved; however, due to the simpler controller and the lack of a measuring system, this is the more cost-effective solution.


Are you looking for a technical solution for your application?

Get your first 3D Design in a few days:

 

Katja Weißbach
Consulting

T +49 351 88585-64
E-Mail

Ronald Schulze
Consulting, Project Management & Engineering
T +49 351 88585-67
E-Mail

 

Francisco Samuel
Consulting &
Project Management
T +49 351 88585-85
E-Mail

 

Elger Matthes
Consulting, Concepts, Innovation & Engineering
T +49 351 88585-82
E-Mail

Our references