KDT600-EDLM
XY Stages
XY Aperture stage (linear motor), travel 385 x 385 mm, aperture 400 mm, rep 0.3 µm, load 23 kg, speed 500 mm/s

Scanning stage with large aperture
This large precision xy stage is designed for maximum repeatability. Accuracy can be achieved with compensation in a cost-saving manner, which is otherwise only reserved for air bearing systems. Polished cross roller guides are used for repeatability of straightness and flatness of + -0.15 µm.
With the large transmitted light, large substrates can also be measured from both sides or with fluoroscopy. It also offers the option of differential measurement to take advantage of full sensor accuracy in measurement applications. Even when the stage is fully moved, an opening of at least 60mm x 60mm is always kept.
Fastest scanning applications with high acceleration
| |
| |
| |
| |
| |
|
Fields of application
Fast scanning applications and dynamic web travel e.g. semiconductor inspection, measuring systems, automatic optical inspection (AOI), measuring devices, differential measurement, replacement for air bearing systems
KDT600-EDLM | -385-EDLM | |
Travel | [mm] | 385 |
Repeatability unidirectional | [μm] | ± 0.3 |
Repeatability bidirectional | [μm] | ± 0.4 |
Accuracy | [μm] | ± 16.6 |
Flatness | [μm] | ± 10 |
Straightness | [μm] | ± 1.7 |
Positioning speed | [mm/s] | 330 |
Max. speed | [mm/s] | 500 |
Max. acceleration | [m/s2] | 3 |
Max. load Fx | [N] | 25 |
Max. load Fy | [N] | 25 |
Max. load Fz | [N] | 230 |
Max. torque Mx | [Nm] | 11 |
Max. torque My | [Nm] | 11 |
Max. torque Mz | [Nm] | 10 |
Pitch | [µrad] | ± 280 |
Yaw | [µrad] | ± 45 |
Length | [mm] | 600 |
Width | [mm] | 600 |
Height | [mm] | 120 |
Aperture | [mm] | 400 |
Motor | Dynamischer Linearmotor (eisenlos), Ironless Dynamic Linear Motor | |
Feedback | Linearmesssystem, Linear Scale |

FMC300
Installation module for dynamic applications and high loads and voltage.

FMC400/450
Multi-axis controller fully ready for tracking, simple creation of own programs.

FMC250/280
Multi-axis controller with increased current and voltage for point-to-point positioning.

PLC
We support integration of our systems into PLC architectures, e.g. Beckhoff

ACS
We support integration of our systems into your ACS environment
Related Products
Almost all atmospheric standard stages are unanodized with UHV lubrication for residual pressures up to 10-6 mbar and min. cleanroom class ISO 6 - or even better - available. Further stages for more demanding environments up to cleanroom class ISO 2, vacuum up to 10E-11 mbar or hard radiation you will find here:
Overview Clean Room & Vacuum Stages Get in touch with our technical consultant
Ja, Lineartische können auch als Hubtische (Z-Richtung) sowie gestapelt (XY-Bewegungen verwendet werden).
Wichtig dafür ist, dass die maximale Kraft in Antriebsrichtung nicht überschritten wird. Die Kraft für die vertikale Positionierung wird in der Spezifikation bei Linear Stages unter Fx angegeben.
Steinmeyer Mechatronik GmbH mainly uses aluminum for the structure of the Linear Stages, because it efficiently dissipates local heat and quickly reaches a thermally stable state. This is a prerequisite for stable, precise systems. The lower stiffness of aluminum compared to steel is compensated by a slightly higher height of the stages or the use of hollow profiles. Note: An aluminum beam and a steel beam sag equally under their own weight!
In special cases, titanium is also used for magnet-free systems.
What surfaces are available?
Various surface options are available. Depending on the application, anodized and cleaned, alternative colors, aluminum cleaned and bare, bilatal or nickel are available for optimal process suitability (e.g. particularly high degrees of purity, resistance to cleaning with chemicals in the field of life science). Special surfaces are often necessary for UV, DUV or EUV (X-ray, gamma on request).
Depending on the requirements, various drive systems can be used. This can be recognized as an abbreviation in the name below:
- Ground ball screws or lead screws with SM (stepper motor), DC motor or AC servo.
- Electrodynamic linear motors (ironless or iron-core).
- Piezomotors such as Piezo-Legs® or Nanomotion®.
Incremental scales made of steel or Zerodur® or Zeromet® are used as a feedback system in most cases. While this is sufficient for accuracy in the single-digit micrometer range, it makes sense to use interferometric position feedback for accuracy requirements below one micrometer. In systems with “open loop”, i.e. without a measuring system, only precision in the double-digit micrometer range can be achieved; however, due to the simpler controller and the lack of a measuring system, this is the more cost-effective solution.
Are you looking for a technical solution for your application?
Get your first 3D Design in a few days:

Katja Weißbach
Consulting
T +49 351 88585-64
E-Mail

Ronald Schulze
Consulting, Project Management & Engineering
T +49 351 88585-67
E-Mail

Francisco Samuel
Consulting &
Project Management
T +49 351 88585-85
E-Mail

Elger Matthes
Consulting, Concepts, Innovation & Engineering
T +49 351 88585-82
E-Mail
Our references
