XYZ positioning system for laboratory inspection | ball screw, DC motor, cross roller, linear measuring system
XYZ Positioning Stages – compact stacked

782300:202.26

 

High-precision 3-axis system for short travels

This XYZ combination consists of the high-precision and durable standard linear axes of the PMT160 which are mounted with an adapter bracket on a KLT310 xy stage. This allows positioning along three linear axes. This combination is suitable for all applications that require perfect flatness, the smallest tolerances for pitch and yaw, and smooth running. The XYZ system is ready to use with controller and operates with reliable parameters.
 

Flexible, ready to use and tested

  • Ideal for setting up and expanding your high-precision measurement technology
  • Very high repeatability up to 0.3 µm
  • Smallest step sizes and highest reliability at comparatively high top speed up to 50 mm/s
  • Perfect flatness of ± 0.5 when positioning medium loads up to 150 N

Optional expandable:

  • Travels up to 100 mm
  • Different motor variants: DC motor or stepper motor
  • Versions for clean room ISO 14644-1
  • Immediate use with pre-configured controller incl. exemplary software

Individual extensions and customizations

Engineering services include the fitting of the systems to your structure and the desired controlls. Furthermore, we develop prototypes and like to adapt the systems to the environmental requirements of your application particle emission, radiation, temperature, precision special parts manufacturing, working height, collision protection, safety concept, compensation factor and filter, sensor mounting, brake, decoupling, special lubrication, special colors, holders, adapters, special motors with pharmaceutical approval, comprehensive documentation, test protocoll, llife cycle tests

Fields of application

Measurement setup, measuring equipment, mold measurement, surface measurement, coordinate measurement, sample inspection, positioning of measuring fibers, special machine construction, inspection of optical components/parts, assembly and connection techniques in silicon photonics

 

782300:202.26

 

X

Y

Z

Used standard component   KT310-DC KT310-DC PMT160-DC

Travel

[mm; deg]

50

50

50

Repeatability unidirectional

[µm; deg]

± 0.5

± 0.5

± 0.3

Repeatability bidirectional

[µm; deg]

± 0.5

± 0.5

± 2.2

Positioning speed

[mm/s; deg/s]

30

30

30

Max. load

[N]

45 45

150

Motor

 

DC-Motor

DC-Motor

DC-Motor

Drive   Ball Screw Ball Screw Ball Screw

Feedback

 

Linear Scale

Linear Scale

Linear Scale

 


Your customized system

By submitting this form, I acknowledge receipt of the Steinmeyer Privacy Policy.

201/5000 Even more axes for your vacuum applications

Almost all atmospheric standard axes are anodized with UHV lubrication for residual pressures up to 10E-6 mbar - or even better - available. Click here for the overview of our standard axes!

Overwiew standard stages   Contact technical consultants

 

Only selected materials, components, and lubricants meet the requirements for low outgassing. In many cases, the use of liquid lubricants is not possible. In addition, the bake-out process places significant stress on the positioning system; thermal stresses occurring at temperatures of up to 140 °C must be taken into account.
All components are designed to be vacuum-compatible and are specially cleaned after manufacturing. Assembly is carried out under cleanroom conditions. For non-magnetic systems, the choice of materials is even more severely restricted.

We offer a wide range of solutions for both UHV systems with the highest performance requirements and non-magnetic assemblies.

The customized adaptation of our positioning systems to existing chambers or setups is carried out in several structured steps. The goal is seamless integration with maximum precision, cleanroom and/or vacuum compatibility, and operational reliability.

Typically, the customization process includes:

  • Analysis of the installation situation (available space, interfaces, loads, degrees of freedom, environmental conditions)
  • Application-specific alignment with respect to vacuum, cleanroom, magnetism, or radiation requirements
  • Mechanical adaptations such as custom adapters, base plates, hole patterns, or installation heights
  • Adaptation of drive, measurement, and cabling concepts, including connector routing, feedthroughs, and cable management
  • Material and lubricant selection tailored to outgassing behavior, particle requirements, and bake-out conditions


The system design is carried out using 3D design and simulation, optionally complemented by prototypes, functional testing, and cleanroom or vacuum preparation.

Our positioning systems are designed for various cleanroom classes in accordance with ISO 14644-1 and can be adapted to the specific application. As standard, we implement systems for ISO 6 to ISO 4. For particularly demanding custom applications—depending on system concept, motion, materials, and lubrication—cleanroom classes down to ISO 2–1 are also possible.

The achievable cleanroom class depends, among other factors, on:

  • the selected mechanics and bearing concept
  • the drive and measurement systems used
  • materials, surface treatments, and lubricants
  • motion profiles and operating conditions, e.g., enclosure and extraction
  • multi-level cleaning processes, handling, and commissioning

All cleanroom systems are appropriately prepared, assembled, and final-cleaned in a cleanroom environment. Upon request, we develop custom solutions precisely tailored to the required cleanroom class and application.

Nearly all atmospheric standard axes are available anodized with UHV lubrication for residual pressures down to 10E-6 mbar — or even better. For systems with stepper or piezo motors, we offer the following vacuum preparation:

  • All parts vacuum-cleaned
  • Liquid lubrication with UHV oil for pressures down to 10-6 mbar
  • Maximum bake-out temperature 80 °C
  • Equipped with Phytron stepper motors
  • Stainless steel components (ball screw, guides, bearings, screws)
  • Kapton or PTFE cabling
  • Kapton or ceramic Sub-D connectors
  • Untreated aluminum surfaces
  • Bores and cavities with venting holes, vented screws, or slotted washers
  • No covers
  • Assembled in our cleanroom
  • Final cleaned
  • Delivered in evacuated, double plastic packaging

 

Click here for more systems:
Overview of our standard axes

Are you looking for a technical solution for your application?

Get your first 3D Design in a few days:

 

Elger Matthes
Consulting, Concepts, Innovation & Engineering
T +49 351 88585-82
E-Mail