PLT240-SM
Linear Stages

High load linear stage (ball screw), travel 200 - 850 mm, rep ± 3.9 µm, load 42 kg, speed 260 mm/s
PLT240-SM

 

Linear stage for high loads

The PLT240-SM provides micro-stepping operation for high repeatability. When operated in combination with an electromagnetic brake, the ball screw drive also allows vertical orientation.

Basis for multi axis combinations

The PLT240-SM is suitable as a basis for axis combinations with additional linear stages in the PLT series or with rotary stages such as the DT240.

Demanding environments

The conditions common to laser engineering and special-purpose machinery manufacture place strict demands on the design of linear stages. The PLT series has been designed especially for use in these industrial environments, and combines a long lifetime with maximum reliability.

 

PLT240   -200-SM -300-SM -400-SM -500-SM -750-SM -850-SM
Travel [mm] 200 300 400 500 750 850
Repeatability unidirectional [μm] ± 3.9 ± 3.9 ± 3.9 ± 3.9 ± 3.9 ± 3.9
Repeatability bidirectional [μm] ± 4.4 ± 4.4 ± 4.4 ± 4.4 ± 4.4 ± 4.4
Accuracy [μm] ± 10.9 ± 13.2 ± 15.4 ± 17.4 ± 22.4 ± 24.4
Flatness [μm] ± 6 ± 9 ± 12 ± 15 ± 25 ± 25
Straightness [μm] ± 3 ± 4.5 ± 6 ± 7.5 ± 11 ± 13
Positioning speed [mm/s] 30 30 30 30 30 30
Max. speed [mm/s] 60 60 60 60 60 60
Max. acceleration [m/s2] 0.6 0.6 0.6 0.6 0.6 0.6
Max. load Fx [N] 420 420 420 420 420 420
Max. load Fy [N] 1010 1010 1010 1010 1010 1010
Max. load Fz [N] 1010 1010 1010 1010 1010 1010
Max. torque Mx [Nm] 35 35 35 35 35 35
Max. torque My [Nm] 45 45 45 45 45 45
Max. torque Mz [Nm] 55 55 55 55 55 55
Pitch [µrad] ± 30 ± 35 ± 40 ± 45 ± 55 ± 60
Yaw [µrad] ± 14 ± 17 ± 20 ± 20 ± 25 ± 30
Resolution [µm] 1.563 1.563 1.563 1.563 1.563 1.563
L1 [mm] 610 710 810 910 1160  

 

Related Products


Angepasstes System für Ihr Gesamtkonzept

Your customized system

Almost all atmospheric standard stages are unanodized with UHV lubrication for residual pressures up to 10-6 mbar and min. cleanroom class ISO 6 - or even better - available. Further stages for more demanding environments up to cleanroom class ISO 2, vacuum up to 10E-11 mbar or hard radiation you will find here:

Overview Clean Room & Vacuum Stages    Get in touch with our technical consultant

Ja, Lineartische können auch als Hubtische (Z-Richtung) sowie gestapelt (XY-Bewegungen verwendet werden).

Wichtig dafür ist, dass die maximale Kraft in Antriebsrichtung nicht überschritten wird. Die Kraft für die vertikale Positionierung wird in der Spezifikation bei Linear Stages unter Fx angegeben.

 

Steinmeyer Mechatronik GmbH mainly uses aluminum for the structure of the Linear Stages, because it efficiently dissipates local heat and quickly reaches a thermally stable state. This is a prerequisite for stable, precise systems. The lower stiffness of aluminum compared to steel is compensated by a slightly higher height of the stages or the use of hollow profiles. Note: An aluminum beam and a steel beam sag equally under their own weight!
In special cases, titanium is also used for magnet-free systems.

What surfaces are available?

Various surface options are available. Depending on the application, anodized and cleaned, alternative colors, aluminum cleaned and bare, bilatal or nickel are available for optimal process suitability (e.g. particularly high degrees of purity, resistance to cleaning with chemicals in the field of life science). Special surfaces are often necessary for UV, DUV or EUV (X-ray, gamma on request).

Depending on the requirements, various drive systems can be used. This can be recognized as an abbreviation in the name below:

  • Ground ball screws or lead screws with SM (stepper motor), DC motor or AC servo.
  • Electrodynamic linear motors (ironless or iron-core).
  • Piezomotors such as Piezo-Legs® or Nanomotion®.

Incremental scales made of steel or Zerodur® or Zeromet® are used as a feedback system in most cases. While this is sufficient for accuracy in the single-digit micrometer range, it makes sense to use interferometric position feedback for accuracy requirements below one micrometer. In systems with “open loop”, i.e. without a measuring system, only precision in the double-digit micrometer range can be achieved; however, due to the simpler controller and the lack of a measuring system, this is the more cost-effective solution.


Are you looking for a technical solution for your application?

Get your first 3D Design in a few days:

 

Katja Weißbach
Consulting

T +49 351 88585-64
E-Mail

Ronald Schulze
Consulting, Project Management & Engineering
T +49 351 88585-67
E-Mail

 

Francisco Samuel
Consulting &
Project Management
T +49 351 88585-85
E-Mail

 

Elger Matthes
Consulting, Concepts, Innovation & Engineering
T +49 351 88585-82
E-Mail

Our references