KDT180-NM
XY Stages

High-precision XY piezo stage, travel 100 x 100 mm, aperture 115 mm, rep ± 0.5 µm, load 5 kg, speed 120 mm/s
KDT180-NM

 

High precision XY stage with aperture

Equipped with piezo motors, the KDT180 is impressive with the smallest increments and high resolution. The XY stage achieves high speed at the same time as high positioning resolution. This XY system is also available as a high vacuum, ultra-high vacuum and non-magnetic version for demanding ambient conditions.

Suitable for demanding environments

  • Ideal for microscopy, research and development and experimental physics
  • High-precision repeatability up to 0.5 µm
  • High speeds with very high positioning resolution
  • Optional with piezo motor, stepper motor or DC motor
  • Vacuum version (HV / UHV) and non-magnetic variants available

Fields of application

High resolution applications in microscopy, super resolution microscopy, scanning microscopy, 3D imaging, screening, vacuum chambers, interferometry, metrology, autofocus systems, biotechnology, semiconductor testing, research, experimental physics, electronics assembly, optics positioning, sample positioning

References

Bioprinting-Based High-Throughput Fabrication of Three-Dimensional MCF-7 Human Breast Cancer Cellular Spheroids | Engineering (2015) Vol.1 Issue (2): 269-274 |

 

Modell KDT180   -100-NM
Travel [mm] 100
Repeatability unidirectional [μm] ± 0.5
Repeatability bidirectional [μm] ± 0.7
Accuracy [μm] ± 8.3
Flatness [μm] ± 10
Straightness [μm] ± 7.5
Positioning speed [mm/s] 80
Max. speed [mm/s] 120
Max. acceleration [m/s2] 1.5
Max. load Fx [N] 8
Max. load Fy [N] 8
Max. load Fz [N] 55
Max. torque Mx [Nm] 0.9
Max. torque My [Nm] 0.9
Max. torque Mz [Nm] 0.7
Pitch [µrad] ± 250
Yaw [µrad] ± 150
Weight [kg] 3
Length [mm] 230
Width [mm] 230
Height [mm] 50
Aperture [mm] 115 x 115
Motor   Nanomotion
Feedback   Linearmesssystem, Linear Scale

 

Related Products


Angepasstes System für Ihr Gesamtkonzept

Your customized system

Almost all atmospheric standard stages are unanodized with UHV lubrication for residual pressures up to 10-6 mbar and min. cleanroom class ISO 6 - or even better - available. Further stages for more demanding environments up to cleanroom class ISO 2, vacuum up to 10E-11 mbar or hard radiation you will find here:

Overview Clean Room & Vacuum Stages    Get in touch with our technical consultant

Ja, Lineartische können auch als Hubtische (Z-Richtung) sowie gestapelt (XY-Bewegungen verwendet werden).

Wichtig dafür ist, dass die maximale Kraft in Antriebsrichtung nicht überschritten wird. Die Kraft für die vertikale Positionierung wird in der Spezifikation bei Linear Stages unter Fx angegeben.

 

Steinmeyer Mechatronik GmbH mainly uses aluminum for the structure of the Linear Stages, because it efficiently dissipates local heat and quickly reaches a thermally stable state. This is a prerequisite for stable, precise systems. The lower stiffness of aluminum compared to steel is compensated by a slightly higher height of the stages or the use of hollow profiles. Note: An aluminum beam and a steel beam sag equally under their own weight!
In special cases, titanium is also used for magnet-free systems.

What surfaces are available?

Various surface options are available. Depending on the application, anodized and cleaned, alternative colors, aluminum cleaned and bare, bilatal or nickel are available for optimal process suitability (e.g. particularly high degrees of purity, resistance to cleaning with chemicals in the field of life science). Special surfaces are often necessary for UV, DUV or EUV (X-ray, gamma on request).

Depending on the requirements, various drive systems can be used. This can be recognized as an abbreviation in the name below:

  • Ground ball screws or lead screws with SM (stepper motor), DC motor or AC servo.
  • Electrodynamic linear motors (ironless or iron-core).
  • Piezomotors such as Piezo-Legs® or Nanomotion®.

Incremental scales made of steel or Zerodur® or Zeromet® are used as a feedback system in most cases. While this is sufficient for accuracy in the single-digit micrometer range, it makes sense to use interferometric position feedback for accuracy requirements below one micrometer. In systems with “open loop”, i.e. without a measuring system, only precision in the double-digit micrometer range can be achieved; however, due to the simpler controller and the lack of a measuring system, this is the more cost-effective solution.


Are you looking for a technical solution for your application?

Get your first 3D Design in a few days:

 

Katja Weißbach
Consulting

T +49 351 88585-64
E-Mail

Ronald Schulze
Consulting, Project Management & Engineering
T +49 351 88585-67
E-Mail

 

Francisco Samuel
Consulting &
Project Management
T +49 351 88585-85
E-Mail

 

Elger Matthes
Consulting, Concepts, Innovation & Engineering
T +49 351 88585-82
E-Mail

Our references