KDT105-PM
XY Stages

XY piezo scanning stage, travel 50 x 50 mm, aperture 50 mm, rep ± 0.3 µm, load 5 kg, speed 7.5 mm/s
KDT105-PM

 

Compact XY aperture stage for demanding environments

Equipped with Piezo motor, the XY Stage with aperture and cross roller bearings achieves smallest steps in the nanometer range with an almost unmatchable positional stability. Considering its size of 150 x 150 x 50 mm, it has a large travel range of 50 mm in the X and Y directions.

  • High repeatability up to ± 0. 3 µm
  • Large aperture of 40 x 40 mm
  • Flexibly adaptable for demanding environmental conditions
Options:
  • With and without aperture
  • Version with nanomotion or piezo motor
  • Flexibly combinable with XYZ-R multi-axis systems e.g. DT105 rotary stage, HT160 lifting stage, MT105
  • Different variants for clean room, radiation, vacuum and magnetism

Fields of application

High-resolution applications in microscopy, semiconductor inspection, bioprinting, super-resolution microscopy, scanning microscopy, 3D imaging, screening, vacuum chambers, semiconductor testing, research, experimental physics, cancer cell research

 

KDT105   -50-PM-L
Travel [mm] 50
Repeatability unidirectional [μm] ± 0.3
Repeatability bidirectional [μm] ± 0.4
Accuracy [μm] ± 4
Flatness [μm] ± 4
Straightness [μm] ± 3
Positioning speed [mm/s] 5
Max. speed [mm/s] 7.5
Max. acceleration [m/s2] 0.1
Max. load Fx [N] 5
Max. load Fy [N] 5
Max. load Fz [N] 45
Max. torque Mx [Nm] 0.7
Max. torque My [Nm] 0.7
Max. torque Mz [Nm] 0.6
Pitch [µrad] ± 180
Yaw [µrad] ± 50
Length [mm] 150
Width [mm] 150
Height [mm] 50
Weight [kg] 2.5
Aperture [mm] 40 x 40
Bearing   Cross Roller Bearings
Motor   Piezo Motor
Feedback   Linear Scale
Resolution Measuring system 0.005, optionally up to 0.001 µm
Material   Anodized Aluminum
Optional features   rotary stage DT105, Z stage HT160 / MT105, custom adapter, bore grid, cable / plugs
Variants clean room  up to clean room class ISO 4 (higher on request)
Variants beam   UV, DUV, EUV (X-ray, gamma on request)
Variants Magnetism magnetic, low-magnetic, magnet-free
Variants vacuum    up to 10E-11 mbar (higher in request)

 

Related Products


Angepasstes System für Ihr Gesamtkonzept

Your customized system

Almost all atmospheric standard stages are unanodized with UHV lubrication for residual pressures up to 10-6 mbar and min. cleanroom class ISO 6 - or even better - available. Further stages for more demanding environments up to cleanroom class ISO 2, vacuum up to 10E-11 mbar or hard radiation you will find here:

Overview Clean Room & Vacuum Stages    Get in touch with our technical consultant

Ja, Lineartische können auch als Hubtische (Z-Richtung) sowie gestapelt (XY-Bewegungen verwendet werden).

Wichtig dafür ist, dass die maximale Kraft in Antriebsrichtung nicht überschritten wird. Die Kraft für die vertikale Positionierung wird in der Spezifikation bei Linear Stages unter Fx angegeben.

 

Steinmeyer Mechatronik GmbH mainly uses aluminum for the structure of the Linear Stages, because it efficiently dissipates local heat and quickly reaches a thermally stable state. This is a prerequisite for stable, precise systems. The lower stiffness of aluminum compared to steel is compensated by a slightly higher height of the stages or the use of hollow profiles. Note: An aluminum beam and a steel beam sag equally under their own weight!
In special cases, titanium is also used for magnet-free systems.

What surfaces are available?

Various surface options are available. Depending on the application, anodized and cleaned, alternative colors, aluminum cleaned and bare, bilatal or nickel are available for optimal process suitability (e.g. particularly high degrees of purity, resistance to cleaning with chemicals in the field of life science). Special surfaces are often necessary for UV, DUV or EUV (X-ray, gamma on request).

Depending on the requirements, various drive systems can be used. This can be recognized as an abbreviation in the name below:

  • Ground ball screws or lead screws with SM (stepper motor), DC motor or AC servo.
  • Electrodynamic linear motors (ironless or iron-core).
  • Piezomotors such as Piezo-Legs® or Nanomotion®.

Incremental scales made of steel or Zerodur® or Zeromet® are used as a feedback system in most cases. While this is sufficient for accuracy in the single-digit micrometer range, it makes sense to use interferometric position feedback for accuracy requirements below one micrometer. In systems with “open loop”, i.e. without a measuring system, only precision in the double-digit micrometer range can be achieved; however, due to the simpler controller and the lack of a measuring system, this is the more cost-effective solution.


Are you looking for a technical solution for your application?

Get your first 3D Design in a few days:

 

Katja Weißbach
Consulting

T +49 351 88585-64
E-Mail

Ronald Schulze
Consulting, Project Management & Engineering
T +49 351 88585-67
E-Mail

 

Francisco Samuel
Consulting &
Project Management
T +49 351 88585-85
E-Mail

 

Elger Matthes
Consulting, Concepts, Innovation & Engineering
T +49 351 88585-82
E-Mail

Our references