DT310-AC
Rotary Stages

Flat rotary stage (AC Servo), travel n x 360 °, aperture ⌀100 mm, rep ± 0.001 °, load 27 kg, speed 180 °/s
DT310-AC

 

Flat rotary stage with large aperture

The high-precision rotary stage, with its flat design and excellent process accuracy, enables a wide range of applications. Due to its large aperture, it is particularly suitable for tasks in the inspection and medical industry.

  • Universally suitable for applications with large aperture
  • Unlimited travel range
  • Load capacity up to 265 N
  • High repeatability up to 0.001 °
  • Optionally available with Stepper Motor or AC servo with motor encoder and various measuring system resolutions

Fields of application

Universal application e.g. micro metrology, medical industry, sample inspection, precision micro assembly, photonics and optics, research and development, experimental physics

 

DT310   -AC -AC-R-W
Travel [deg] n x 360 n x 360
Repeatability unidirectional [deg] ± 0.001 ± 0.001
Repeatability bidirectional [deg] ± 0.015 ± 0.002
Accuracy [deg] ± 0.024 ± 0.003
Excentric runout [µm] ± 4 ± 4
Wobble [µrad] ± 15 ± 15
Positioning speed [deg/s] 123 79
Max. Speed [deg/s] 184 118
Max. acceleration [deg/s2] 2080 1331
Max. load Fz [N] 267 267
Max. torque Mx, My [N] 45.7 45.7
Max. torque Mz [N] 4 29.3
Length [mm] 305 305
Width [mm] 310 310
Height [mm] 60 60
Turntable Ø [mm] 100 100
Aperture Ø [mm] 180 180
Weight [kg] 9.0 9.0
Bearing   Thin-section bearing
Motor   AC Motor
Transmission   Belt, Harmonic Drive
Feedback   Motor Encoder
Surface Coating   Anodized Aluminum, Nickel
Optional Features   Electrical and pneumatic rotary feed-through,
superfinished turntable for optimum axial run-out, brake,
rotation limiter, cable routing, reversing hard stop, sealing air, extraction system
Versions for Cleanroom   Clean Room Class ISO 4 (higher on request)
Versions for Radiation   EUV, DEV, UV (X-ray and gamma on request)
Versions with Lower Magnetism   -
Versions for Vacuum   -

 

Related Products


Angepasstes System für Ihr Gesamtkonzept

Your customized system

Almost all atmospheric standard stages are unanodized with UHV lubrication for residual pressures up to 10-6 mbar and min. cleanroom class ISO 6 - or even better - available. Further stages for more demanding environments up to cleanroom class ISO 2, vacuum up to 10E-11 mbar or hard radiation you will find here:

Overview Clean Room & Vacuum Stages    Get in touch with our technical consultant

Ja, Lineartische können auch als Hubtische (Z-Richtung) sowie gestapelt (XY-Bewegungen verwendet werden).

Wichtig dafür ist, dass die maximale Kraft in Antriebsrichtung nicht überschritten wird. Die Kraft für die vertikale Positionierung wird in der Spezifikation bei Linear Stages unter Fx angegeben.

 

Steinmeyer Mechatronik GmbH mainly uses aluminum for the structure of the Linear Stages, because it efficiently dissipates local heat and quickly reaches a thermally stable state. This is a prerequisite for stable, precise systems. The lower stiffness of aluminum compared to steel is compensated by a slightly higher height of the stages or the use of hollow profiles. Note: An aluminum beam and a steel beam sag equally under their own weight!
In special cases, titanium is also used for magnet-free systems.

What surfaces are available?

Various surface options are available. Depending on the application, anodized and cleaned, alternative colors, aluminum cleaned and bare, bilatal or nickel are available for optimal process suitability (e.g. particularly high degrees of purity, resistance to cleaning with chemicals in the field of life science). Special surfaces are often necessary for UV, DUV or EUV (X-ray, gamma on request).

Depending on the requirements, various drive systems can be used. This can be recognized as an abbreviation in the name below:

  • Ground ball screws or lead screws with SM (stepper motor), DC motor or AC servo.
  • Electrodynamic linear motors (ironless or iron-core).
  • Piezomotors such as Piezo-Legs® or Nanomotion®.

Incremental scales made of steel or Zerodur® or Zeromet® are used as a feedback system in most cases. While this is sufficient for accuracy in the single-digit micrometer range, it makes sense to use interferometric position feedback for accuracy requirements below one micrometer. In systems with “open loop”, i.e. without a measuring system, only precision in the double-digit micrometer range can be achieved; however, due to the simpler controller and the lack of a measuring system, this is the more cost-effective solution.


Are you looking for a technical solution for your application?

Get your first 3D Design in a few days:

 

Katja Weißbach
Consulting

T +49 351 88585-64
E-Mail

Ronald Schulze
Consulting, Project Management & Engineering
T +49 351 88585-67
E-Mail

 

Francisco Samuel
Consulting &
Project Management
T +49 351 88585-85
E-Mail

 

Elger Matthes
Consulting, Concepts, Innovation & Engineering
T +49 351 88585-82
E-Mail

Our references