DT155-NM
Rotary Stages

High-resolution rotary stage (Piezo Motor), travel n x 360°, aperture ⌀ 78 mm, rep ± 0.0015 °, load 7 kg, speed 120 °/s
DT155-NM

 

Highly precise with dynamic imaging

  • Compact and outstanding flat (200 x 155 x 35 mm)
  • Repeatability up to ± 0.0015 °
  • Large aperture of 78 mm
Options:
  • Version for cleanroom, vacuum and beam
  • Combinable with the XY Aperture Stage KDT180-NM
  • Customized development with 3D design, prototypes, series production

Fields of application

High-precision and dynamic microscopy, e.g. electron microscope, ion microscope, scanning electron microscope, wafer handling, wafer inspection, semiconductor quality control, semiconductor research

 

DT155   -1NM-W -2NM-W -3NM-W -4NM-W
Number of Motors   One Motor Two Motors Three Motors Four Motors
Travel [deg] n x 360 n x 360 n x 360 n x 360
Repeatability unidirectional [deg] ± 0.0015 ± 0.0015 ± 0.0015 ± 0.0015
Repeatability bidirectional [deg] ± 0.0027 ± 0.0027 ± 0.0027 ± 0.0027
Accuracy [deg] ± 0.0039 ± 0.0039 ± 0.0039 ± 0.0039
Excentric runout  [µm] ± 5 ± 5 ± 5 ± 5
Wobble [µrad] ± 90 ± 90 ± 90 ± 90
Positioning speed [deg/s] 123 123 123 123
Max. speed [deg/s] 185 185 185 185
Max. acceleration [deg/s2] 2090 2090 2090 2090
Max. load Fz [N] 71 71 71 71
Max. torque Mx, My [N] 5.0 5.0 5.0 5.0
Max. torque Mz [N] 0.6 1.2 1.8 2.4
Length [mm] 200 200 200 200
Width [mm] 155 155 155 155
Height [mm] 35 35 35 35
Turntable Ø [mm] 150 150 150 150
Aperture Ø [mm] 78 78 78 78
Weight [kg] 0.8 1.6 2.4 3.0
Bearing   Thin-section Bearing
Motor   Nanomotion (Piezo)
Transmission   Friction, Ultrasonic
Feedback   Angular Scale
Surface Coating   Anodized Aluminum, Cleaned Aluminum
Optional Features  

Customer-specific adapters or bore grids,
combination with standard XY stages, linear axes or lifting stages

Versions for Cleanroom    Clean Room Class ISO 4 ((higher in request)
Versions for Radiation   EUV, DEV, UV (X-ray and gamma on request)
Versions with Lower Magnetism   low-magnetic (magnet-free on request)
Versions for Vacuum    10-8 mbar (higher in request)

 

Related Products


Angepasstes System für Ihr Gesamtkonzept

Your customized system

Almost all atmospheric standard stages are unanodized with UHV lubrication for residual pressures up to 10-6 mbar and min. cleanroom class ISO 6 - or even better - available. Further stages for more demanding environments up to cleanroom class ISO 2, vacuum up to 10E-11 mbar or hard radiation you will find here:

Overview Clean Room & Vacuum Stages    Get in touch with our technical consultant

Ja, Lineartische können auch als Hubtische (Z-Richtung) sowie gestapelt (XY-Bewegungen verwendet werden).

Wichtig dafür ist, dass die maximale Kraft in Antriebsrichtung nicht überschritten wird. Die Kraft für die vertikale Positionierung wird in der Spezifikation bei Linear Stages unter Fx angegeben.

 

Steinmeyer Mechatronik GmbH mainly uses aluminum for the structure of the Linear Stages, because it efficiently dissipates local heat and quickly reaches a thermally stable state. This is a prerequisite for stable, precise systems. The lower stiffness of aluminum compared to steel is compensated by a slightly higher height of the stages or the use of hollow profiles. Note: An aluminum beam and a steel beam sag equally under their own weight!
In special cases, titanium is also used for magnet-free systems.

What surfaces are available?

Various surface options are available. Depending on the application, anodized and cleaned, alternative colors, aluminum cleaned and bare, bilatal or nickel are available for optimal process suitability (e.g. particularly high degrees of purity, resistance to cleaning with chemicals in the field of life science). Special surfaces are often necessary for UV, DUV or EUV (X-ray, gamma on request).

Depending on the requirements, various drive systems can be used. This can be recognized as an abbreviation in the name below:

  • Ground ball screws or lead screws with SM (stepper motor), DC motor or AC servo.
  • Electrodynamic linear motors (ironless or iron-core).
  • Piezomotors such as Piezo-Legs® or Nanomotion®.

Incremental scales made of steel or Zerodur® or Zeromet® are used as a feedback system in most cases. While this is sufficient for accuracy in the single-digit micrometer range, it makes sense to use interferometric position feedback for accuracy requirements below one micrometer. In systems with “open loop”, i.e. without a measuring system, only precision in the double-digit micrometer range can be achieved; however, due to the simpler controller and the lack of a measuring system, this is the more cost-effective solution.


Are you looking for a technical solution for your application?

Get your first 3D Design in a few days:

 

Katja Weißbach
Consulting

T +49 351 88585-64
E-Mail

Ronald Schulze
Consulting, Project Management & Engineering
T +49 351 88585-67
E-Mail

 

Francisco Samuel
Consulting &
Project Management
T +49 351 88585-85
E-Mail

 

Elger Matthes
Consulting, Concepts, Innovation & Engineering
T +49 351 88585-82
E-Mail

Our references