MP220-4 Miniature XY-Phi-Delta Positioning System, Cardan on XY Aperture Stage | Hexapod Alternative | Travel XY 10 mm Rx Ry 4° | High Loads up to 10 kg
Compact Multi Axis Stages

AB_EM TO MP250-4
MP220-4 Miniature XY-Phi-Delta Positioning System, Cardan on XY Aperture Stage | Hexapod Alternative | Travel XY 10 mm Rx Ry 4° | High Loads up to 10 kg - Compact Multi Axis Stages

 

Cardan on XY Stage with aperture

This XY Phi Delta Aligner combines three vertically operating precision axes connected to a movable load plate. The load plate can be tilted in two axes and the aperture stage for a additional XY motion.

  • Ideal for optical and active alignment for high loads up to 10 kg
  • Large aperture for high-resolution scanning applications
  • Good price-performance ratio and very long lifetime

Options:

  • Rotation around the main axis with an additional rotary stage
  • Various, high-resolution measuring systems
  • Extended travels in XY direction
  • Version for cleanroom, vacuum and beam
  • Customized development with 3D design, prototypes, series production

Application fields

Optical & active alignment, high-resolution applications in microscopy, optical inspection systems, 3D imaging, screening, incident light measurement, transmitted light measurement, interferometry, metrology, autofocus systems, biotechnology, semiconductor testing

 

MP220-4 XYRxRy
Travel[mm](20) 10(20) 1044
Repeatability unidirectional  [µm]± 0.5± 0.5± 0.003± 0.003
Repeatability bidirectional  [µm]± 1± 1± 0.01± 0.01
Positioning speed[mm/s]220.10.1
Max. speed[mm/s]440.20.2
Max. Load[N]00 100
Length x width x height[mm]235 x 220 x 100
Aperture[mm]Ø 45
Drive Lead ScrewLead ScrewLead ScrewLead Screw
Screw type M5,55625x0,6096
Motor Stepper MotorStepper MotorStepper MotorStepper Motor
Feedback Open LoopOpen LoopOpen LoopOpen Loop
Material Anodized Aluminum
Optional features Rotary stage, sample holder, calibreless energy supply for unlimited rotation
Variants clean room up to cleanroom class ISO 4 (higher on request)
Variants beamUV, DUV (EUV, X-ray, gamma on request)
Variants Magnetismmagnetic (low-magnetic on request)
Variants vacuum up to 10E-6 mbar (higher on request)
Note Fixed pivot position 25 mm below stage surface. For fixed inspection point, correct with offset when tilting.

 

Your customized system